Plug-In Solar in Utah

The law, and what it means for your design.

Plug-in solar by state › Utah

In effect

Law checked Oct 13, 2026 against HB 340 enrolled · Last change: per-device limit clarified; purpose and liability added · Change log

Utah passed the country’s first plug-in solar law in 2025, without a single no vote. A device up to 1,200 W that plugs into a standard 120 V outlet can skip the utility’s interconnection process entirely. The law is short and leaves a lot unsaid, so the design choices are mostly yours.

What you can build today

Inspector’s call. The device must meet the most recent NEC, and the law has no size waiver.

Always an option: a permitted, hardwired system under NEC 690 and 705 with your utility’s approval, or an off-grid power station that never connects to house wiring. UL Solutions notes the 2026 NEC “does not recognize the use of plug-in photovoltaic (PIPV) modules”; NFPA expects them in the 2029 edition (source). Where a law requires the NEC and gives no size waiver, the inspector decides. Sun Safe’s reading, not legal advice.

Limit
1,200 W per device
Law
HB 340 (Solar Power Amendments)
Signed
March 25, 2025
Effective
May 7, 2025

What the law says

Size limit1,200 W “maximum power output” per device
How it’s measuredPer device. The law doesn’t say AC or DC and doesn’t set a total for a home with more than one device.
ConnectionA standard 120 V AC outlet. The device must be “moveable.”
ListingCertified by UL or another nationally recognized testing lab (NRTL). Must meet the current National Electrical Code (NEC). UL 3700 isn’t named.
Outage protectionRequired: a feature that keeps the device from energizing the house wiring during a power outage.
Electrician or permitNot mentioned in the law.
Utility noticeNone required.
Utility approval and feesThe utility can’t require its approval, any fee related to the system, or extra equipment.
Power sent to the gridNot part of net metering (§ 54-15-601(1)).
PurposeMeant mainly to offset part of the home’s own use (§ 54-15-102(13)(c)).
Utility liabilityThe utility isn’t liable for damage or injury from the device (§ 54-15-601(3)(b)).
Renters and HOAsNot addressed.

In the law’s words

Short excerpts from HB 340 (2025), enrolled (Utah Code §§ 54-15-102, 54-15-601), quoted as written and checked word for word against the official text on October 13, 2026; each with what it means for a plug-in design.

10 excerpts with what each means

What it means for your design

Designs that fit, and one that doesn’t

FitsTwo 400 W panels on one APsystems EZ1-LV (900 VA) plugged into an outdoor GFCI receptacle on its own circuit.
FitsOne 450 W panel on a Hoymiles HiFlow Pro 450 LV.
Our advice: avoidTwo EZ1-LVs (1,800 VA total) sharing one home. The law limits each device to 1,200 W and sets no home total; Sun Safe’s conservative reading keeps the home at 1,200 W.

The engineering behind it

Why the circuit matters as much as the law, in four short points.

Circuit current, continuous output, outdoor outlets, AC vs panel watts

Why the circuit matters. A plug-in inverter pushes current into a branch circuit from the outlet end. The breaker in your panel only sees the current coming from the panel, not what the inverter adds. With other loads on the same circuit, part of the wire can carry the breaker’s full rating plus the inverter’s output without anything tripping. At 1,200 W the inverter adds 10 A at 120 V. That’s why we recommend a dedicated circuit for any plug-in system, even where the law doesn’t require one.

Continuous output. Code treats inverter output as continuous and sizes the circuit at 125% of it (NEC 705.28): 1,200 W is 10 A, times 1.25 is 12.5 A, which fits a 15 A circuit. Anything over 1,440 W needs a 20 A circuit.

Outdoors. Outdoor receptacles need GFCI protection (NEC 210.8) and an in-use weatherproof cover (NEC 406.9).

AC, not panel watts. These laws limit what the inverter puts out, not what the panels are rated for. You can put more panel on a small inverter; it trims the brightest hours and fills out the rest of the day. The Designer models that trimming hour by hour.

Design your systemSee Utah on the map

Questions

Is plug-in solar legal in Utah?

Yes. HB 340 took effect May 7, 2025. A certified device up to 1,200 W plugged into a standard 120 V outlet is exempt from the utility’s interconnection requirements and agreements.

Do I need an electrician for plug-in solar in Utah?

The law doesn’t say either way. It requires the device to meet the NEC and be certified by UL or another testing lab. We recommend a practicing electrician install or check it.

Will my Utah utility pay me for the power I send back?

No. Plug-in devices aren’t part of Utah’s net metering program, so only the power your home uses at the time saves money.

Sources

Bill text read September 29, 2026; law checked October 13, 2026 by Casey Schuyler, NABCEP PV Associate and O&M Associate Technician, Sun Safe LLC. Information for planning, not legal advice. Laws change; verify against the bill and your local authority having jurisdiction. Sun Safe’s position: installations should be code-compliant, and a practicing electrician is recommended.