Patent pending • verification and reference documents
Verify: Vermont Secretary of State business search → search “Sun Safe LLC”.
Provisional applications aren’t published or searchable at the USPTO. The filing receipt is below; confirmation through patent counsel on request.
Founder, Sun Safe LLC · LinkedIn
Verify: NABCEP Professional Directory → search by name. Certificates: Contact page.
EMS Coordinator / Fire Captain, Killington Fire & Rescue · LinkedIn
Witnessed the Oct 22, 2026 Phase 1 field testing on site, entered readings and signed each trial log:
Background, The Mountain Times, May 24, 2023: “Killington Fire and Rescue hires two” · “Mark Foote becomes Killington’s first full-time paid firefighter”.
Application 64/026,462, filed Apr 2, 2026, mailed Jun 8, 2026.
Filed Apr 12, 2026 (11 V.S.A. § 4023), record 489840.
Beer-Lambert transmission vs. 7 W/m² and 125 mA across documented peak irradiance. Rev. B, Oct 21, 2026: test-module Isc 8.71 A (nameplate), cited sources, 125 mA as a measurement-noise gate.
How the lineman’s rubber gloves went from a practical field fix to a standard every maker builds to, and why the new light-blocking products for PV, each tested its own way, now need the same. Updated Oct 24, 2026, with Phase 1 results, design levels and 15 linked sources.
The completed log for each published trial: Side 1 raw data, Side 2 results, signatures and photo record, as generated by the v29 log. Open to view or print; Download to save. Current is the BT270 clamp reading with the sheet on.
Protocol, instruments, trial sequence by log box (with the photo record), Side 2 analysis, threshold derivations, results for all seven trials, recorded deviations, OD from both meter pairs, scaling to any monofacial module, levels met and sourced references. Monofacial modules only. V18, Oct 24, 2026.
Backstrom & Dini, Underwriters Laboratories, Nov 29, 2011 (DHS Fire Prevention and Safety grant).
| §9.1 cover, 1 layer | Voc | Isc | UL’s call |
|---|---|---|---|
| 4 mil black plastic | 33 V | 0 A | Safe |
| Blue all-purpose tarp | 126 V | 2.1 A | Electrocution |
| Canvas salvage tarp | 3.2 V | 0 A | Safe |
| Red vinyl salvage tarp | 124 V | 1.8 A | Electrocution |
| Full sun (4 × 230 W) | 148 V | 8.1 A |
DC current through the body, as UL 2011 classifies its results (PDF p. 23). A source cannot push more current through a person than its short-circuit current.
| Voltage / current threshold | Value | Source |
|---|---|---|
| DC shock hazard (PV) | 100 V and 40 mA | NFPA 70E 2027 First Draft, FR-102, proposed 390.2(2) (draft text) |
| Rapid shutdown, outside the array boundary | ≤ 30 V within 30 s | NEC 2017–2023 690.12(B)(1); 30 V chosen as touch-safe in wet conditions per (Brooks & Rogers, IAEI 2015) |
| Rapid shutdown, inside the array boundary | ≤ 80 V within 30 s, or a listed hazard control system | NEC 2017–2023 690.12(B)(2) |
| Sun Safe Stage 1 (S1) gate | < 125 mA | Measurement-noise gate (meter floor) — not a shock limit |
Values are for reference only and do not replace an NFPA 70E shock risk assessment or PPE.
The working log used to record Phase 1 test data on site, with automatic Side 2 results. For Sun Safe use; the published trials are in the trial records above.